Does the spacing between different circuits meet safety standards to prevent short circuits and leakage?

Publish Time: 2024-08-14
In the design of Machine Internal Wiring, the spacing between different circuits is a critical safety consideration.

Ensuring that the wiring spacing meets safety standards is critical to preventing short circuit and leakage accidents. Short circuit refers to the flow of current in an unexpected path, usually due to the small spacing between the lines, resulting in unexpected contact or arcing. Leakage refers to the leakage of current from the normal circuit path to the part where there should be no electricity.

The safety standard for wiring spacing is based on a comprehensive consideration of multiple factors. The first is the operating voltage and current of the circuit. Higher voltages and currents require larger spacing to avoid breaking through the air or insulating materials, thereby causing short circuits. Second, the performance of the insulating material used for wiring will also affect the required spacing. If the insulating material is of poor quality or aged, a larger spacing is required to provide adequate protection.

In actual machine design, engineers need to carefully evaluate the characteristics and potential risks of different circuits. For example, a larger spacing is usually required between strong and weak current circuits to prevent strong current from interfering with weak current signals and to avoid the danger of short circuits that may be caused by strong current.

In addition, the working environment of the machine will also affect the wiring spacing. In a hot, humid or dusty environment, the insulation performance may deteriorate, so the wiring spacing needs to be increased to ensure safety.

In order to verify whether the wiring spacing meets the safety standards, a series of tests and evaluations are usually carried out. This may include simulating the voltage and current loading under actual working conditions to check whether there is a discharge phenomenon; or performing an insulation resistance test to determine whether the insulation performance meets the requirements.

If the wiring spacing does not meet the safety standards, serious consequences may occur. Short circuits may cause fires, equipment damage, and even casualties. Leakage may cause electric shock hazards, affecting the normal operation and reliability of the equipment.

Therefore, in the design, manufacturing and maintenance of the machine, the relevant safety standards must be strictly followed, and the Machine Internal Wiring spacing must be accurately designed and tested to ensure the safe operation of the machine, protect the safety of personnel and equipment, and reduce potential risks and losses.
×